Product specifications, technical parameters:
Product model |
LE-1801 |
Product color |
Black |
Rated voltage |
220V~ |
Rated frequency |
50Hz |
Rated power |
30W |
Rated humidification quantity |
200ml/h~1000ml/h |
Tank capacity |
1000ml~5000ml |
Gross weight |
19.5KG |
Container number |
8 sets |
Packing size |
720×530×400MM |
Standards |
GB4706.1-2005 GB4706.48-2009 |
Noise |
≤35dB |
Ultrasonic humidifier directions for use
Thank you for purchasing our company ultrasonic humidifier, in order to make your correct use and maintenance of the machine, please read the instructions carefully before use, and please keep for future access.
Product structure that
Method of use
Place and method of use
●Please will the machine in the distance computer, television, speaker and so on electric appliance 2 meters outside the place (FIG. 1);
●Please send this machine had placed in stationary desktop, lest machine tilt, causing internal components damage (FIG. 2);
●Please do not be placed in the machine easily met curtain place (FIG. 3);
●Please do not will be placed in the sunshine easy to direct and close to the furnace and other heat source place (FIG. 4);
Operation steps
●The first time use humidifier, packing should be out of the humidifier, put stationary;
●A water tank, open the tank cover, the water tank filled with water. Cover and water tank cover, smoothly on the stand
●Fox will nozzle on the tank upper slot
●Switch on the power, turn on the power switch (no water it is strictly prohibited to boot), the power indicator light is lit, humidifier started to spray
●Regulation fog quantity choose knob, choose the size of appropriate amount of fog,
●Just on the use of a few minutes, there is a small amount of fog from the overflow is normal phenomenon
note
1.This machine suitable working environment for 5-40 ℃, relative humidity < 80% RH. Please do not at 0 ℃ below environment using the machine;
2.Using temperature below 40 ℃ water (suggest using pure water);
3.Add water, please hands holding steady, avoid water tank accident slide, to person or product damage;
4.Will humidifier power cord plug into the socket, and ensure good contacts; Do not use wet hand plug power plug, lest produce electric shock;
5.Do not use humidifier placed on children palpable place to use;
6.It is strictly prohibited to in flammable and explosive gas environment using the machine;
7.Such as the machine accident dumping, please immediately cut off power source;
8.The machine in the work if you have abnormal sound or smell, please immediately off and unplug the power supply plug, if you need maintenance, must by manufacturer or its maintenance department related personnel;
9.Please do not in product studio the fog mouth away and avoid wet mesa;
10.The machine work, do not touch the water in the tank or water components;
11.Please do not in the water tank anhydrous state forcibly boot work;
12.Cleaning, maintenance and moving the machine before you turn off the switch, unplug the power supply plug;
13.Please do not when clean water inflow or splash into the machine interior, lest damage machine internal parts;
14.Please do not in the water not to join the company production and expediting of any additives;
15.The power cord aging, knot, plug damage shall immediately stop the use, if you want to change, must by the manufacturer or its maintenance department related personnel;
16.Long time when not in use. Please close product switch, and will power plug from the socket pluck up,
17.If the product is out of order, please contact the local after-sale service center, please do not do STH without authorization and machine maintenance.
Cleaning and maintenance
Daily maintenance and maintenance
●Some local water quality is hard, calcium and magnesium content is higher, and part of the areas use bleaching powder and applicability, in the use of humidifier, part of the calcium magnesium ion will with water spray out together, diffuse in the object surface and ground, drying to the formation of the "white" the same thermonatrite, part of the precipitation in the atomization tablet and tank surface, form scale, this is not pure water cause, if atomization tablet surface junction on scale, can affect humidifier add wet effect.
Keep the humidifier clean method
●Use pure water humidifying; Weekly cleaning spray tablet, tanks, stand; Often change cistern of Chen water, keep clean humidifier, Humidifier long time need not when, in the flume tank and don’t save water;
●Please collect the parts and dry cleaning after loading the original packaging.
Cleaning spray tablet and stand method
●Will cleaner into a frame inside, and then add in 60 ℃ or so warm water, make cleaner completely dissolved; For two minutes, then use xiaomao brush gently scrub atomization tablet surface, until to remove scale, also can at the same time cleaning stand. Finally clean with clear water base and atomization piece surface can.
Cleaner and atomization piece of maintenance
●Cleaner please away from children’s storage;
●Cleaner don’t entrance, eye, if carelessly, please immediately use tap water cleaning,
●Do not use the our company production and expediting cleaner spray slices.
●Do not use objects to scrape atomization tablet
Common faults and processing method
If your humidifier can not work normally, please you in requirements maintenance service for the following check before.
Fault phenomenon |
Cause analysis |
Elimination method |
The power indicator
not bright |
Power supply has been on |
Pick good power supply, clockwise
rotation on/off knob |
Float stuck |
Clean and gently pull move float,
make it smooth |
Extrusive water mist
have peculiar smell |
The new machine |
Open the tank, the water tank in open
shade placed 12 hours |
Water dirty or water storage for a
long time |
Cleaning tank, in clean water |
Spray a little
|
Atomization piece of scaling |
Cleaning spray tablet |
Water dirty or water storage for a
long time |
Cleaning tank, in clean water |
The fog did not cover mouth |
Will the fog mouth by positioning
cover is |
Electric schematic diagram
Caveat: the user please don’t to open machine maintenance, should by professionals or send maintenance center maintenance, otherwise easy to produce risk.
Warranty registration card
Name |
Ultrasonic humidifier
|
Product Model |
|
User Name |
|
Phone |
|
Zip Code |
|
Address |
|
Selling store |
|
Invoice number |
|
|
|
Date of purchase |
Day Month Year |
Maintenance requirements
1.One-year warranty period, the Company will be responsible for free repair.
2.When requesting a repair, please bring this card to the local or the nearest
designated repair point handle maintenance.
3.Even if one of the following occurs during the warranty period, and not covered by warranty.
1), due to use, or not in accordance with the instructions on where to place undue cause failure;
2), since the fall, caused by the failure of the collision;
3), self-assembly and disassembly repair the fault;
4), did not produce the purchase invoice and warranty card;
5), due to earthquakes, wars, floods, fires and other natural factors caused the fault does not
belong to the scope of the warranty. |
Warranty card
Customers |
Name |
|
|
Address |
|
Phone |
|
Date of purchase |
|
Part of the guarantee please refer to fill in,
and stamp dealers stamp, otherwise invalid.
1, since the purchase of this product from the
date one year under normal conditions of use,
free service.
2, more than on a fixed period with For-for spare
parts, maintenance fee received appropriate.
3, during the warranty period, if the following
circumstances without a free repair.
1).Failed to produce a guarantee or who purchase
certificate (invoice or receipt).
2).Over the warranty period.
3).Dismantling or transformation of the damage
caused.
4).Due to an error / negligence or human damage
caused by improper use.
5).The average family use (such as long-term use
in the harsh environment of the place) the failure or
damage caused by.6).Appearance by using natural
the sewage old. |
Inspector |
|